Effect of glide path preparation on apical debris extrusion of rotary and reciprocating single-file systems: OneShape versus WaveOne

Objectives: To assess the effect of glide path on the amount of apically extruded debris after instrumentation with WaveOne and OneShape. Materials & Methods: Forty-eight extracted human mandibular incisors were assigned to 4 groups. In groups 1 and 2, preparation was completed with WaveOne, in groups 3 and 4 canals were prepared with OneShape. Before instrumentation, in groups 1 and 3, glide path was created with PathFile 1, 2, and 3 at working length, whereas in groups  2 and 4, glide path was not performed. The weight of the extruded debris for each group was calculated by comparing the pre- and post-instrumentation weights of the eppendorf tubes. The time required for reaching full WL was also recorded. Data were analysed by Kruskal–Wallis and Mann–Whitney U tests. Results: There was no difference in the amount of debris extruded between the single file systems (P=0.234). Time required to reach full WL was significantly decreased by creating a glide path (P< 0.05). Conclusions: Creation of a glide path does not significantly affect the apically extruded debris.

Objectives: To assess the effect of glide path on the amount of apically extruded debris after instrumentation with WaveOne and OneShape. Materials & Methods: Forty-eight extracted human mandibular incisors were assigned to 4 groups. In groups 1 and 2, preparation was completed with WaveOne, in groups 3 and 4 canals were prepared with OneShape. Before instrumentation, in groups 1 and 3, glide path was created with PathFile 1, 2, and 3 at working length, whereas in groups  2 and 4, glide path was not performed. The weight of the extruded debris for each group was calculated by comparing the pre- and post-instrumentation weights of the eppendorf tubes. The time required for reaching full WL was also recorded. Data were analysed by Kruskal–Wallis and Mann–Whitney U tests. Results: There was no difference in the amount of debris extruded between the single file systems (P=0.234). Time required to reach full WL was significantly decreased by creating a glide path (P< 0.05). Conclusions: Creation of a glide path does not significantly affect the apically extruded debris.

Dergi Adı Cumhuriyet Dental Journal
Dergi Cilt Bilgisi 18
Dergi Sayısı 1
Sayfalar 1 - 8
Yayın Yılı 2015
Eser Adı
[dc.title]
Effect of glide path preparation on apical debris extrusion of rotary and reciprocating single-file systems: OneShape versus WaveOne
Yazar
[dc.contributor.author]
Aktemur, Sevinç Türker
Yazar
[dc.contributor.author]
Koçak, Sibel
Yazar
[dc.contributor.author]
Koçak, Mustafa Murat
Yazar
[dc.contributor.author]
Sağlam, Baran Can
Yayın Yılı
[dc.date.issued]
2015
Yayın Türü
[dc.type]
article
Özet
[dc.description.abstract]
Objectives: To assess the effect of glide path on the amount of apically extruded debris after instrumentation with WaveOne and OneShape. Materials & Methods: Forty-eight extracted human mandibular incisors were assigned to 4 groups. In groups 1 and 2, preparation was completed with WaveOne, in groups 3 and 4 canals were prepared with OneShape. Before instrumentation, in groups 1 and 3, glide path was created with PathFile 1, 2, and 3 at working length, whereas in groups  2 and 4, glide path was not performed. The weight of the extruded debris for each group was calculated by comparing the pre- and post-instrumentation weights of the eppendorf tubes. The time required for reaching full WL was also recorded. Data were analysed by Kruskal–Wallis and Mann–Whitney U tests. Results: There was no difference in the amount of debris extruded between the single file systems (P=0.234). Time required to reach full WL was significantly decreased by creating a glide path (P< 0.05). Conclusions: Creation of a glide path does not significantly affect the apically extruded debris.
Özet
[dc.description.abstract]
Objectives: To assess the effect of glide path on the amount of apically extruded debris after instrumentation with WaveOne and OneShape. Materials & Methods: Forty-eight extracted human mandibular incisors were assigned to 4 groups. In groups 1 and 2, preparation was completed with WaveOne, in groups 3 and 4 canals were prepared with OneShape. Before instrumentation, in groups 1 and 3, glide path was created with PathFile 1, 2, and 3 at working length, whereas in groups  2 and 4, glide path was not performed. The weight of the extruded debris for each group was calculated by comparing the pre- and post-instrumentation weights of the eppendorf tubes. The time required for reaching full WL was also recorded. Data were analysed by Kruskal–Wallis and Mann–Whitney U tests. Results: There was no difference in the amount of debris extruded between the single file systems (P=0.234). Time required to reach full WL was significantly decreased by creating a glide path (P< 0.05). Conclusions: Creation of a glide path does not significantly affect the apically extruded debris.
Kayıt Giriş Tarihi
[dc.date.accessioned]
2019-12-23
Açık Erişim Tarihi
[dc.date.available]
2019-12-23
Yayın Dili
[dc.language.iso]
eng
Konu Başlıkları
[dc.subject]
Diş Hekimliği
Haklar
[dc.rights]
info:eu-repo/semantics/openAccess
ISSN
[dc.identifier.issn]
1302-5805
İlk Sayfa Sayısı
[dc.identifier.startpage]
1
Son Sayfa Sayısı
[dc.identifier.endpage]
8
Dergi Adı
[dc.relation.journal]
Cumhuriyet Dental Journal
Dergi Sayısı
[dc.identifier.issue]
1
Dergi Cilt Bilgisi
[dc.identifier.volume]
18
Tek Biçim Adres
[dc.identifier.uri]
http://www.trdizin.gov.tr/publication/paper/detail/TVRjMU5ESTRPQT09
Tek Biçim Adres
[dc.identifier.uri]
https://hdl.handle.net/20.500.12628/350
Görüntülenme Şehir
Görüntülenme Ülke
İndirme Şehir
İndirme Ülke
Görüntülenme & İndirme
Görüntülenme
11
09.12.2022 tarihinden bu yana
İndirme
1
09.12.2022 tarihinden bu yana
Son Erişim Tarihi
02 Mayıs 2023 11:30
Google Kontrol
Tıklayınız
Altmetric
https://hdl.handle.net/20.500.12628/350">
debris extruded groups  required apically significantly instrumentation WaveOne amount OneShape analysed recorded Mann–Whitney reaching Conclusions Creation Kruskal–Wallis Results difference between creating decreased single eppendorf systems weights Forty-eight groups assigned incisors mandibular extracted Methods preparation
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.


Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.