A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples

A newly synthesized polystyrene-g-polyoleic acid-g-polyethylene glycol graft copolymer (PoleS-PEG) was used as adsorbent in the solid phase microextraction of selenium ions by using electrothermal atomic absorption spectrometry (ETAAS). Neodymium magnet was used for separation of analyte ions. Various analytical parameters such as pH, adsorbent amount, mixing time, eluent solution, sample volume, etc. were optimized. The matrix effects of some cations and anions were also studied. The capacity of the adsorbent was found 11.5 mg g -1 . The preconcentration factor was found to be 50. The detection limit (LOD) and quantification limit (LOQ) were found 6.06 ng L -1 and 20 ng L -1 , respectively. The calibration curve was linear in the range of 0.02–4.0 µg L -1 . Relative standard deviation was found 3.2%. The accuracy of the method was provided by using standard reference materials. The optimized method was successfully applied to natural water and food samples. © 2019 Elsevier Ltd

Eser Adı
[dc.title]
A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples
Yazar
[dc.contributor.author]
Açıkkapı, Ayşe Nihan
Yazar
[dc.contributor.author]
Tüzen, Mustafa
Yazar
[dc.contributor.author]
Hazer, Baki
Yayın Yılı
[dc.date.issued]
2019
Yayıncı
[dc.publisher]
Elsevier Ltd
Yayın Türü
[dc.type]
article
Özet
[dc.description.abstract]
A newly synthesized polystyrene-g-polyoleic acid-g-polyethylene glycol graft copolymer (PoleS-PEG) was used as adsorbent in the solid phase microextraction of selenium ions by using electrothermal atomic absorption spectrometry (ETAAS). Neodymium magnet was used for separation of analyte ions. Various analytical parameters such as pH, adsorbent amount, mixing time, eluent solution, sample volume, etc. were optimized. The matrix effects of some cations and anions were also studied. The capacity of the adsorbent was found 11.5 mg g -1 . The preconcentration factor was found to be 50. The detection limit (LOD) and quantification limit (LOQ) were found 6.06 ng L -1 and 20 ng L -1 , respectively. The calibration curve was linear in the range of 0.02–4.0 µg L -1 . Relative standard deviation was found 3.2%. The accuracy of the method was provided by using standard reference materials. The optimized method was successfully applied to natural water and food samples. © 2019 Elsevier Ltd
Kayıt Giriş Tarihi
[dc.date.accessioned]
2019-12-23
Açık Erişim Tarihi
[dc.date.available]
2019-12-23
Yayın Dili
[dc.language.iso]
eng
Konu Başlıkları
[dc.subject]
Electrothermal atomic absorption spectrometry
Konu Başlıkları
[dc.subject]
Graft copolymer
Konu Başlıkları
[dc.subject]
Magnetic solid phase microextraction
Konu Başlıkları
[dc.subject]
Selenium
Konu Başlıkları
[dc.subject]
Water and food samples
Künye
[dc.identifier.citation]
Acikkapi, A. N., Tuzen, M. ve Hazer, B. (2019). A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples. Food Chemistry, 284, 1–7. doi:10.1016/j.foodchem.2019.01.091
Haklar
[dc.rights]
info:eu-repo/semantics/closedAccess
ISSN
[dc.identifier.issn]
0308-8146
Sponsor YAYINCI
[dc.description.sponsorship]
2017/58
Sponsor YAYINCI
[dc.description.sponsorship]
The authors would like to thanks the Unit of the Scientific Research Projects of the Gaziosmanpasa University (Project number: 2017/58) for the financial support. Dr. Mustafa Tuzen thanks to Turkish Academy of Sciences for financial support. The authors thanks to proof reading service of Zonguldak Bulent Ecevit University.
İlk Sayfa Sayısı
[dc.identifier.startpage]
1
Son Sayfa Sayısı
[dc.identifier.endpage]
7
Dergi Adı
[dc.relation.journal]
Food Chemistry
Dergi Cilt Bilgisi
[dc.identifier.volume]
284
Tek Biçim Adres
[dc.identifier.uri]
https://dx.doi.org/10.1016/j.foodchem.2019.01.091
Tek Biçim Adres
[dc.identifier.uri]
https://hdl.handle.net/20.500.12628/3991
Görüntülenme Sayısı ( Şehir )
Görüntülenme Sayısı ( Ülke )
Görüntülenme Sayısı ( Zaman Dağılımı )
Görüntülenme
690
09.12.2022 tarihinden bu yana
İndirme
1
09.12.2022 tarihinden bu yana
Son Erişim Tarihi
20 Eylül 2024 21:33
Google Kontrol
Tıklayınız
adsorbent optimized method standard preconcentration quantification natural Elsevier factor detection samples reference deviation materials provided successfully accuracy applied respectively Relative 02–4 linear calibration selenium magnet Neodymium (ETAAS) spectrometry absorption atomic electrothermal microextraction analyte (PoleS-PEG) copolymer
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms