Procedural outcomes of double vs. single fluoroscopy for fixing intertrochanteric femur fractures

Objective This study compares reducing radiation and operation time between single and double C-arm fluoroscopy in the treatment of intertrochanteric femur fractures with intramedullary nails. Patients and methods Forty four patients participated in the study. Patients were divided into two groups as single (23 patients) and double fluoroscope (21 patients). The time of preparation, the duration of the surgery, the total amount of blood loss, and the total duration of radiation exposure were compared, retrospectively. The collo-diaphyseal angle was compared with that of the contralateral hip on postoperative radiographs. Furthermore, the tip-apex distance and the position of the screws in the femoral head were recorded. Results The mean preparation periods, collo-diaphyseal angles and blood loss did not differ between groups. In the double-fluoroscopy group, the duration of surgery was 15.9 min shorter (p < 0.001), and the radiation time was 25.7 s shorter (p < 0.001). Conclusion The double fluoroscopy technique can significantly reduce surgical and radiation exposure times during surgery.

Yazar Kara, Adnan
Celik, Haluk
Seker, Ali
Uzun, Metin
Sonmez, Mehmet Mesut
Erdil, Mehmet
Yayın Türü Article
Tek Biçim Adres https://hdl.handle.net/20.500.12628/3164
Tek Biçim Adres 10.1007/s00402-016-2473-1
Konu Başlıkları Intertrochanteric femur fracture
Double fluoroscopy
Intramedullary nail
Koleksiyonlar Araştırma Çıktıları | WoS | Scopus | TR-Dizin | PubMed | SOBİAD
PubMed İndeksli Yayınlar Koleksiyonu
WoS İndeksli Yayınlar Koleksiyonu
Dergi Adı ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
Dergi Cilt Bilgisi 136
Dergi Sayısı 7
Sayfalar 929 - 934
Yayın Yılı 2016
Eser Adı
[dc.title]
Procedural outcomes of double vs. single fluoroscopy for fixing intertrochanteric femur fractures
Yazar
[dc.contributor.author]
Kara, Adnan
Yazar
[dc.contributor.author]
Celik, Haluk
Yazar
[dc.contributor.author]
Seker, Ali
Yazar
[dc.contributor.author]
Uzun, Metin
Yazar
[dc.contributor.author]
Sonmez, Mehmet Mesut
Yazar
[dc.contributor.author]
Erdil, Mehmet
Yayın Yılı
[dc.date.issued]
2016
Yayıncı
[dc.publisher]
SPRINGER
Yayın Türü
[dc.type]
article
Özet
[dc.description.abstract]
Objective This study compares reducing radiation and operation time between single and double C-arm fluoroscopy in the treatment of intertrochanteric femur fractures with intramedullary nails. Patients and methods Forty four patients participated in the study. Patients were divided into two groups as single (23 patients) and double fluoroscope (21 patients). The time of preparation, the duration of the surgery, the total amount of blood loss, and the total duration of radiation exposure were compared, retrospectively. The collo-diaphyseal angle was compared with that of the contralateral hip on postoperative radiographs. Furthermore, the tip-apex distance and the position of the screws in the femoral head were recorded. Results The mean preparation periods, collo-diaphyseal angles and blood loss did not differ between groups. In the double-fluoroscopy group, the duration of surgery was 15.9 min shorter (p < 0.001), and the radiation time was 25.7 s shorter (p < 0.001). Conclusion The double fluoroscopy technique can significantly reduce surgical and radiation exposure times during surgery.
Açıklama
[dc.description]
WOS: 000378564500006
Açıklama
[dc.description]
PubMed: 27155881
Kayıt Giriş Tarihi
[dc.date.accessioned]
2019-12-23
Açık Erişim Tarihi
[dc.date.available]
2019-12-23
Yayın Dili
[dc.language.iso]
eng
Konu Başlıkları
[dc.subject]
Intertrochanteric femur fracture
Konu Başlıkları
[dc.subject]
Double fluoroscopy
Konu Başlıkları
[dc.subject]
Intramedullary nail
Haklar
[dc.rights]
info:eu-repo/semantics/closedAccess
ISSN
[dc.identifier.issn]
0936-8051
ISSN
[dc.identifier.issn]
1434-3916
İlk Sayfa Sayısı
[dc.identifier.startpage]
929
Son Sayfa Sayısı
[dc.identifier.endpage]
934
Dergi Adı
[dc.relation.journal]
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
Dergi Sayısı
[dc.identifier.issue]
7
Dergi Cilt Bilgisi
[dc.identifier.volume]
136
Tek Biçim Adres
[dc.identifier.uri]
https://dx.doi.org/10.1007/s00402-016-2473-1
Tek Biçim Adres
[dc.identifier.uri]
https://hdl.handle.net/20.500.12628/3164
Görüntülenme Sayısı ( Şehir )
Görüntülenme Sayısı ( Ülke )
Görüntülenme Sayısı ( Zaman Dağılımı )
Görüntülenme
166
09.12.2022 tarihinden bu yana
İndirme
1
09.12.2022 tarihinden bu yana
Son Erişim Tarihi
25 Mayıs 2024 00:19
Google Kontrol
Tıklayınız
radiation double surgery duration preparation compared collo-diaphyseal patients) groups shorter exposure single between Patients fluoroscopy Results periods recorded angles during surgical femoral reduce differ significantly double-fluoroscopy technique Conclusion position screws Objective distance fractures patients methods
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms