Filtreler
Araştırmacılar
Comparative evaluation of push-out bond strength of Neo MTA Plus with Biodentine and white ProRoot MTA

Aktemur Türker S. | Uzunoğlu E. | Bilgin B.

Article | 2017 | Journal of Adhesion Science and Technology31 ( 5 ) , pp.502 - 508

Objective: The aim of this in vitro study was to evaluate the bond strength of a new calcium silicate cement, Neo MTA Plus (Avalon Biomed Inc. Bradenton, FL, U.S.A) by comparing ProRoot MTA and Biodentine. Material and Methods: Sixty dentin slices were instrumented to achieve a diameter of 1.3 mm. Group 1: white ProRoot MTA, group 2: Biodentine, group 3: Neo MTA Plus–G (powder mixed with gel), group 4: Neo MTA Plus–W (powder mixed with distilled water) were loaded into cavities. The push-out bond strength values were measured. Data were analyzed using Welch ANOVA with Bonferroni correction p = 0.05. Failure modes (adhesive, cohesive . . ., and mixture) were analyzed. Results: The highest bond strength value was recorded in Neo MTA Plus mixed with gel (5.23 ± 1.78 MPa), whereas white ProRoot MTA (2.57 ± 0.66 MPa) had the lowest. Bond strength values of Neo MTA Plus mixed either with gel or with distilled water were statistically different from both white ProRoot MTA and Biodentine (2.61 ± 0.70 MPa) (p Daha fazlası Daha az


6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve çerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.


Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.