İnce, Elif | İnce, Mine | Topaloğlu, Alikemal
Article | 2018 | Membrane Water Treatment9 ( 5 ) , pp.343 - 351
As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention . . .time increases, membrane fouling rate decreases. © 2018 Techno-Press, Ltd Daha fazlası Daha az
İnce, Mahir | Topaloğlu, Alikemal | İnce, Mine
Article | 2018 | Membrane Water Treatment9 ( 1 ) , pp.33 - 42
Microscopic examination of the activated sludge and morphological characterization of the flocs provides detailed information about the treatment process. The aim of this study is to investigate the morphological parameters of flocs obtained from a thermophilic jet loop membrane bioreactor (JLMBR) in different sludge retention times (SRTs), considering EPS and SMP concentration, hydrophobicity, zeta potential. The results showed that irregularity decreased with the increasing SRT. The compactness value was calculated to be less than 1 for all SRTs. However, the sludge had a more compact structure when the SRT increased. Zeta potenti . . .al increased whereas hydrophobicity and floc size reduced, with increasing SRT. Furthermore, 2-D porosity calculated using the hole ratio was higher at greater SRTs. Hence, there was a significant correlation between the results obtained using the imaging technique and operation conditions of thermophilic JLMBR. © 2018 Techno-Press, Ltd Daha fazlası Daha az
İnce, Mine | Topaloğlu, Alikemal
Article | 2018 | Membrane Water Treatment9 ( 4 ) , pp.245 - 253
The aim of this study is to investigate the membrane fouling in a thermophilic membrane bioreactor (TMBR) operated different sludge retention times (SRTs). For this purpose, TMBR was operated at four different SRTs (10, 30, 60 and 100 days). Specific cake resistance (?), cake resistance, gel resistance, total resistance, MFI (modified fouling index) and FDR (flux decrease ratio) were calculated for all SRTs. It was observed that flux in the membrane increases with rising SRT although the sludge concentrations in the TMBR increased. The steady state flux was found to be 31.78; 34.70; 39.60 and 43.70 LMH (Liter/m2/h) for the SRTs of 1 . . .0, 30, 60 and 100 days respectively. The concentrations of extracellular polymeric substance (EPS) and soluble microbial product (SMP) decreased with increasing SRT. The membrane fouling rate was higher at shorter SRT and the highest fouling rate appeared at an SRT of 10 d. Both the sludge cake layer and gel layer had contribution to the fouling resistance, but the gel layer resistance value was dominant in all SRTs. © 2018 Techno-Press, Ltd Daha fazlası Daha az